Questions and answers

Какие функции Умного дома Вы получите? Изучить можно здесь! www.insyte.club


The controller automatically receives the IP address from the router. What's the problem?
The controller automatically receives the IP address from the router. What's the problem?
Questions on equipment

The controller does not support automatic obtaining IP addresses (DHCP). The IP address is configured in the controller settings in the Configurator.


When connecting the light sensor voltage with stable illumination jumps in the range of 0.5-1 V. what is it?
When connecting the light sensor voltage with stable illumination jumps in the range of 0.5-1 V. what is it?
Questions on equipment

Most likely the problem is in fluorescent lighting. The lamp gives a flicker, which is invisible to the eye but recorded by the sensor.


The ports on the spider to connect a 3-wire analog sensor?
The ports on the spider to connect a 3-wire analog sensor?
Questions on equipment The connection is made as follows:

Spider Sensor
14 black
13 red
9 blue
10 connect 14

Hung the controller. What to do?
Hung the controller. What to do?
Questions on equipment

Re-boot of the controller to its factory state. On the menu: Controller -> Restart -> To its factory state


When you add the IR commands, an error occurs. What to do?
When you add the IR commands, an error occurs. What to do?
Questions on software

Right-click the device, select edit type and check the box editable fields in the field of education. Then save and try again.


The controller is not found, or password is not correct!
The controller is not found, or password is not correct!
Questions on software

Question:
LD_ConfiguratorPro finds the connected controller Spider
I enter the admin password, but it turns out the error "Controller not found, or password is not correct!".
OS finds the controller fine, the drivers are installed.
Windows...


How to work with variables in Iridium Mobile?
How to work with variables in Iridium Mobile?
Questions on software

There are several ways to work with variables in Iridium Mobile.
1. Add to the list of devices Spider, click on it, right click and select "Edit type". Add a new field, select the type Holding Register and the address. Address variables in...


What is the Modbus RTU Protocol?
What is the Modbus RTU Protocol?
General questions

A detailed description of the Modbus Protocol can be studied via the following link.


How the system works and LanDrive?
How the system works and LanDrive?
General questions

LanDrive system consists of a Central controller and network Executive modules. Their connection is on a 5-wire bus: 2 – food 2 - information lines A and B. 1 - ground. For installation use 8-wire cable FTP twisted-pair with shield, stranded each cor...


How to make food for the whole network LanDrive?
How to make food for the whole network LanDrive?
General questions

The power supply is carried out in any stable power supply constant voltage 12 volt.


What is the RS-485 standard?
What is the RS-485 standard?
General questions

A detailed description of the RS-485 standard can be explored on the following the link.


What is the maximum length of twisted pair cable can be?
What is the maximum length of twisted pair cable can be?
General questions

According to the specification standard RS-485 maximum cable length twisted pair can be 1200 meters. However, given this fact, it should be noted that at such distances it is necessary to reduce the baud rate of devices on the network. Usually, even ...


How to lay a twisted pair?
How to lay a twisted pair?
General questions

Cabling at the facility is carried out in several ways.
First, from the Central controller extends the beginning of the bus and through each point where you want execution units. It is desirable to feed the cable through the ceilings, sockets, switches...


Where to locate the Central controller and Executive modules?
Where to locate the Central controller and Executive modules?
General questions

The Central controller may be located in a special shield and in any available place. Modules, depending on performance, may be located in the glasses of switches, sockets, suspended ceilings, niches or as technological in a single shield.


Is it possible to lay a “twisted pair” topology “Star”?
Is it possible to lay a “twisted pair” topology “Star”?
General questions

Not desirable, but in desperate situations, when the tire is either already paved or impossible to do without branches, every ray of the tyre must be confirmed by the resistors of the required resistance encountered in a specific beam. In the most ex...


How to connect the terminals of the Executive module to the bus?
How to connect the terminals of the Executive module to the bus?
General questions

The connection is effected by crimping the conductors of the bus special tips with the help of a specialized crimping tool. Supply terminals and the crimp tool is a Sales INSYTE Electronics.


What you can control equipment in the system LanDrive?
What you can control equipment in the system LanDrive?
General questions

In the system LanDrive available all currently existing methods of control systems "smart house". IR remote, keyboard control, control touch panels, computer control, remote control through Internet, control with mobile phone.


How to implement the control system using IR remote?
How to implement the control system using IR remote?
General questions

Control with IR remote controls is implemented by means of modules LD2-IR. This module is able to maintain a large number of IR commands to audio -video equipment and air conditioners. Save commands is accomplished by sending with the remote in progr...


How to implement a control system with touch panels?
How to implement a control system with touch panels?
General questions

The touch panel has a special software which creates a virtual "desktops" with virtual buttons that, when clicked there is a programmed action. The panel performs wired or wireless communication with the Central system controller transmitti...


How to implement a management system using the keys?
How to implement a management system using the keys?
General questions

There is significant portion of customers "smart home" that wants to control the system with a group of keys are located in one place. It is enough to set in place a group of uncommitted, or standard electrical switches connected in multiba...


  • 1